Dom ProduktyStrażnik Piorunów

500KV HV Substation Lightning Arrester for Lighting Surge Protection Self Standing

Chiny Hangzhou Yongde Electric Appliances Co.,Ltd Certyfikaty
Chiny Hangzhou Yongde Electric Appliances Co.,Ltd Certyfikaty

——

Im Online Czat teraz

500KV HV Substation Lightning Arrester for Lighting Surge Protection Self Standing

500KV HV Substation Lightning Arrester for Lighting Surge Protection Self Standing
500KV HV Substation Lightning Arrester for Lighting Surge Protection Self Standing

Duży Obraz :  500KV HV Substation Lightning Arrester for Lighting Surge Protection Self Standing

Szczegóły Produktu:

Place of Origin: Zhejiang,China(Mainland)
Nazwa handlowa: YONGDE
Orzecznictwo: ISO9001/KEMA
Model Number: YH10W5-60

Zapłata:

Minimum Order Quantity: 1pcs
Cena: negotiation
Packaging Details: carton
Delivery Time: 21days per container
Payment Terms: T/T or western Union or L/C or PayPal
Supply Ability: 30,000pcs per month
Szczegółowy opis produktu
Type: Polymer MOA Housed: Polymeric
Rated voltage: 60KV Nominal Current: 10KA
Function: Over-Voltage Protection Structure: Self-Standing
Color: Gray Standard: IEC
High Light:

station type lightning arrester

,

lightning arrester in substation

500KV HV Substation Type Polymer Lightning Arrester for Lighting Surge Protection​

 

Polymer Lightning Arrester Description:

 

YongDe Surge Arresters can be applied to a variety of systems including substation equipment, AC-DC converters, railway power system and power distribution units ranging from 0.25kV to 765kV systems. These surge arresters demonstrate excellent protection properties. 

 

Polymer Lightning Arrester Specifications:

 

Type YH10W5-60/159
Rated voltage---------kV 60
MOCV ----------------kV 48
Nominal Current-------kV 5
Residual voltage of steep impulse----at 5kA(kV) 173
8/20µS Residual voltage of lightning impulse current kV(Peak value)-----at 5kA(kV) 159
Residual voltage of switching impulse current kV (peak value)----at 1kA (kV) 127
1mA D.C reference voltage (kV) 85
Line discharge level 2
2mS long duration impulse current A 600
4/10µS High current impulse kA 100
Lightning impulse withstand kV 325
Power frequency voltage withstand(dry/wet)kV 140
0.1S TOV--------------kV 72
1S TOV----------------kV 69
10S TOV---------------kV 66
1200S TOV-------------kV 60
Creepage distance ----mm 2070
Material employed in series non-linear resistor Zinc Oxide

 

Different creepage distance variants and a wide range of connectors and accessories allow customized solutions – please contact us! 

Szczegóły kontaktu
Hangzhou Yongde Electric Appliances Co.,Ltd

Osoba kontaktowa: Matt

Wyślij zapytanie bezpośrednio do nas (0 / 3000)